GODIAG GT100 with CAS4 Test Platform Test Key Synchronization

GODIAG GT100 with GODIAG CAS4 CAS4+ Test Platform can not only perform key programming (add new key and all keys lost), but also synchronize test and troubleshooting. This post will share the guide to use it to test whether the programmed key synchronizes with CAS4/CAS4+ module before installing the module back to the car.

 

 

All devices required:

GODIAG GT100 OBD2 Break Out Box ECU Connector

GODIAG CAS4 CAS4+ Programming Test Platform

CAS4 or CAS4 module

BMW Key

Godiag Gt100 With Cas4 Test Platform Test Key 1

 

Connection:

Firstly, connect GODIAG CAS4 Test Platform with CAS4/CAS4+ module

Godiag Gt100 With Cas4 Test Platform Test Key 2

Next, plug CAS4 CAS4+ Test Platform connector to GODIAG GT100 directly

Godiag Gt100 With Cas4 Test Platform Test Key 3

Then fasten the screw of test platform

Godiag Gt100 With Cas4 Test Platform Test Key 4

Finally, supply power to GODIAG GT100,  turn on “POWER” and “12 V (30)” button

Godiag Gt100 With Cas4 Test Platform Test Key 5

 

Main operation steps:

1.When the key synchronizes with CAS4 CAS4+:

Plug the key into the coil of GODIAG CAS4 Test Platform

Then the CANL, BAT+, CHAS GND, SIG GND and CANH indicators will be on

Godiag Gt100 With Cas4 Test Platform Test Key 6

But the CANL and CANH indicators will turn off immediately. The reason is that the “Start” button of CAS4 test platform has not been turn on.

Godiag Gt100 With Cas4 Test Platform Test Key 7

Once press the “Start” button, the “Dash” indicator will be on and the corresponding indicators also turn on.

Godiag Gt100 With Cas4 Test Platform Test Key 8

Press “Start” button to turn off and then turn on again

After 4 or 5 minutes, the data transmission will be closed

Godiag Gt100 With Cas4 Test Platform Test Key 9

When remove the key from CAS4 test platform, it will resend the data and the corresponding indicators will be on.

Godiag Gt100 With Cas4 Test Platform Test Key 10

2.When the key doesn’t synchronize with CAS4 CAS4+:

When it is out of sync, there is no response after plugging the key.

The indicators are also off and the data will not be sent.

Godiag Gt100 With Cas4 Test Platform Test Key 11

Even though press “Start” button, the indicators will go out.

 

That’s all!

More tutorials of GODIAG GT100 with CAS4 test platform are coming soon!